CN
HOMEABOUT USINDUSTRY INFO SX1302 LORAWAN GATEWAY MODULE LORAWAN1302 TRANSMIT...

SX1302 LoRaWan Gateway Module LoRaWan1302 Transmit Power Test

By sdga:NiceRF Wireless Technology Co., Ltd

NiceRF: How to test the transmit power of SX1302 LoRaWan gateway module LoRaWan1302

 

1. SX1302 LoRaWan Gateway Module LoRaWan1302(433MHz) to be tested

SX1302 LoRaWan Gateway Module LoRaWan1302

 

2. Test Tools & Instruments

Frequency spectrograph, DC power supply, electrostatic bracelet, ammeter, product function test rack

DC power supply

DC power supply

 

Product function test rack -- place the LoRaWan gateway module LoRaWan1302 in the fixture of the test rack in the correct direction

Product function test rack -- place the LoRaWan gateway module LoRaWan1302 in the fixture of the test rack in the correct direction

 

Spectrum analysis

Spectrum analysis

 

3. Test indicators

3.1 Working voltage: DC5V

3.2 Transmitter power: > 29dBm

3.3 Center frequency error: < 1KHz

3.4 Emission current: < 2000mA

 

4. SX1302 LoRaWan Gateway Module LoRaWan1302 test process

4.1 Wear an electrostatic bracelet and set the power supply voltage at 5V.

Wear an electrostatic bracelet and set the power supply voltage at 5V.

4.2 Set the central frequency point of the frequency spectrograph as working frequency point of the module to be tested. See the LCD display for the specific frequency point.

Set the frequency of the demo board to be consistent with the module to be tested, and connect the display and hand mark.

For example, 433MHz module, the parameter settings are shown in the following figure:

Band: 433M

PA: 9

mode: TX

Set the frequency of the demo board to be consistent with the module to be tested

See the table below for specific frequency parameters:

Operating frequency rangeSetting frequency pointSetting bandwidthEmission current(mA)Transmitting power(dBm)
433MHz433.175MHz135KHz<2000>29
470MHz490.525MHz135KHz<2000>29
868MHz868.525MHz135KHz<2000>29
915MHz925.525MHz135KHz<2000>29

 

4.3 Put the module into the test fixture in the correct direction. When powered on, the GPO-GP4 light on the test rack shall be on for one second and then off, and press the run key of the test rack. The frequency spectrograph shall display the power higher than 29dBm and the frequency within the range, as shown in the figure below:

LoRaWan gateway LoRaWan1302 spectrum analysis test

4.4 During communication test, the blue light on the receiving board should flash.

During communication test, the blue light on the receiving board should flash.

4.5 Only when the tests in above 4.3 and 4.4 are both normal, the product is qualified.

 

5. SX1302 LoRaWan Gateway Module LoRaWan1302 attention:

The power connection between DC power supply and test fixture should not be reversed, and the DC power supply voltage shouldnot be adjusted arbitrarily after setting.

LoRaWan Gateway Module LoRaWan1302 spectrum analyzer parameters cannot be changed after setting.

All power supply instruments shouldbe reliably grounded.

Contact Us

 +86-755-23080616

 sales@nicerf.com

Website: https://www.nicerf.com/

Address: 309-314, 3/F, Bldg A, Hongdu business building, Zone 43, Baoan Dist, Shenzhen, China

Contact Us
Privacy Policy

Privacy Policy

· Privacy Policy

There is currently no content available


           

Email:sales@nicerf.com

Tel:+86-755-23080616

Address:309-314, 3/F, Bldg A, Hongdu business building, Zone 43, Baoan Dist, Shenzhen, China


×